Chi tiết sản phẩm

PHÂN CỰC KẾ TỰ ĐỘNG, MÀN HÌNH CẢM ỨNG

Chia sẻ: 

Model: Polatronic M Touch Series
NSX: Smidtch Haensch - Đức

Phân cực kế tự động cho phép đo liêu tục với độ phân giải cao, có thể sử dụng cho ngành thực phẩm

Polarimeter of the M-Series are high resolution polarimeters with following features:

  • High-performance Polarimeter for different applications
  • Robust metal housing
  • Highly accurate and reproducible measuring results over the whole measuring range in no time at all
  • Continuous measurements for control of changes in concentration, depending on time or reaction
  • Adopted User friendly Operation System displayed by a broad 7“ TFT Touchscreen
  • Easy to calibrate by certified Quartz Control Plates (SQCP, TQCP)
  • Modern and robust design for rough environments
  • Internal measuring data storage
  • Documentation according to GLP/GMP, 21 CFR part 11 ready, corresponding software optionally available
  • Very long-lasting LED light source
  • Extremely low noise
  • Minimal maintenance effort
  • Remote diagnostics and servicing

Checking/Calibration

As the interference filters, which are used in circle polarimeters, suffer from age- and environment depending alteration, it might be necessary to check the wavelength accuracy periodically and to readjust the wavelength in case it’s out of range. This can be done with sucrose solutions or quartz control plates since the optical properties of sucrose solution and quartz are almost identical. Sucrose solutions are not very stable and have to be renewed regularly. Checking a polarimeter by a quartz plate is a much more reliable method.

Quartz control plates are long-term stable examination standards for polarimeter. The sample room of SCHMIDT + HAENSCH polarimeter permits the vertical movement of quartz control plates as well as the free rotation (±360°) around their own axis. Only by a rotation it is possible to check if the plates are mounted without strain and permit an examination of the polarimeter according to processing regulations of international standards like ICUMSA and OIML.

Technical data:

Brand Polartronic M Touch
Measurement scale °Optical Rotation / °Specific Rotation / °Z International Sugar Scale / % Concentration / freely definable scales
Measuring range ± 360°  /  ± 259°Z
Resolution 0,001° / 0,01°Z
Precision ± 0,005° / ± 0,015°Z**
Reproducibility ± 0,005° / ± 0,015°Z
Sensitivity up to OD 5
Response time approx. 4 sec
Wavelength one or two fixed
Measurement mode continuous

Temperature

Temperature measurement If temperature sensor with appropriate tubes is used / T-Cell Peltier tubes
Temperature control sample with appropriate tubes via external water bath / Peltier temperature controlled sample tubes
Temperature control range depends on the water bath / 18 - 40 °C
Resolution depends on the water bath / 0.01 °C
Precision depends on the water bath / ± 0.03 °C
Reproducibility depends on the water bath / 0.05 °C

Additional information

Measuring tubes up to 200 mm length
Ambient temperature +10 – +40 °C
Light source LED
Display 7” TFT touch screen, 800x480 Pixel, 16 Bit colours
Operation Touch screen, keyboard*, mouse*, bar code reader*, remote via PC*
Interfaces/communication RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), analog, W-LAN/LAN*

Standard models

  M100 T (589 nm) 
M101 T (882 nm) 
M202 T (589 and 882 nm)

Conformity

Standards*** International Pharmacopoea, ASTM, ICUMSA and others